For women over 40, mammography is a necessary yet annoying procedure to endure every year or two. The technique, while valuable for reducing breast cancer deaths, is less than ideal because it exposes patients to X-ray radiation and requires their breasts to be painfully squished between plates. The plates flatten the breast so the X-rays can more easily pass through it and produce a clear image.
Early detection has been shown to increase breast cancer survival rates, but many women avoid having their mammograms taken as often as they should because of the discomfort involved. A 2013 study found that as many as half of women who were avoiding their mammograms cited pain as the reason why.
Mammography also has trouble with breasts, such as those in young women, that are "radiographically dense," or somewhat opaque to X-rays. And mammography tends to overdiagnose, causing around half of women to receive a false-positive diagnosis at some point in their lives.
The researchers say they have developed something better: a laser-sonic scanner that can find tumors in as little as 15 seconds by shining pulses of light into the breast. The scanning system, known as photoacoustic computed tomography, or PACT.
PACT works by shining a near-infrared laser pulse into the breast tissue. The laser light diffuses through the breast and is absorbed by oxygen-carrying hemoglobin molecules in the patient's red blood cells, causing the molecules to vibrate ultrasonically. Those vibrations travel through the tissue and are picked up by an array of 512 tiny ultrasonic sensors around the skin of the breast. The data from those sensors are used to assemble an image of the breast's internal structures in a process that is similar to ultrasound imaging, though much more precise. PACT can provide a clear view of structures as small as a quarter of a millimeter at a depth of 4 centimeters. Mammograms cannot provide soft-tissue contrast with the level of detail in PACT images, senior author says.
Because the laser light at the currently used wavelength is so strongly absorbed by hemoglobin, PACT can construct images that primarily show the blood vessels present in the tissue being scanned. That's useful for finding cancer because many tumors grow their own blood vessels, surrounding themselves with dense networks of vascular tissue. Those vessels provide the tumors with large amounts of blood and allow the tumors to grow quickly.
During a PACT scan, the patient lies face down on a table that has a recess containing ultrasonic sensors and the laser. One breast at a time is placed in the recess, and the laser shines into it from underneath. Since the scan is quick, taking only 15 seconds, the patient can easily hold their breath while being scanned, and a clearer image can be developed.
"This is the only single-breath-hold technology that gives us high-contrast, high-resolution, 3-D images of the entire breast," senior author says.
The speed with which a PACT scan can be performed gives it advantages over other imaging techniques. For example, magnetic resonance imaging (MRI) scans can take 45 minutes. MRI scans are also expensive and sometimes requires contrast agents to be injected into the patient's blood.
"Gadolinium, for example, is a common contrast agent for MRI which is not totally innocuous," senior author says. "Gadolinium may cause nausea and vomiting, and can remain in the brain for years, with unknown long-term effects. In comparison, PACT is entirely safe; the blood serves as an intrinsic contrast agent, and the laser exposure is well within the safety limits."
In a recent pilot study, the researchers scanned the breasts of eight women using PACT, and correctly identified eight of the nine breast tumors that were present.
The PACT technology has already been licensed by a company, of which the senior author is a founder and shareholder, that plans to commercialize it and conduct large-scale clinical studies, senior author says.
http://www.caltech.edu/news/laser-sonic-scanner-aims-replace-mammograms-finding-breast-cancer-82512
https://www.nature.com/articles/s41467-018-04576-z
Latest News
DNA attached to nanoparticl…
By newseditor
Posted 29 Mar
Neighboring synapses shape…
By newseditor
Posted 29 Mar
Complete vascularization of…
By newseditor
Posted 28 Mar
Immune cells identified as…
By newseditor
Posted 28 Mar
TB blood test which could d…
By newseditor
Posted 27 Mar
Other Top Stories
How a common virus triggers blood cancer
Read more
Monoclonal antibody against cancer mutant protein Ras developed!
Read more
How brain cancer spreads
Read more
How circadian 'clock' may influence cancer pathway
Read more
Cancer cells 'talk' to their environment, and it talks back
Read more
Protocols
Spatial proteomics in neuro…
By newseditor
Posted 28 Mar
All-optical presynaptic pla…
By newseditor
Posted 23 Mar
Epigenomic tomography for p…
By newseditor
Posted 20 Mar
A mouse DRG genetic toolkit…
By newseditor
Posted 17 Mar
An optogenetic method for t…
By newseditor
Posted 13 Mar
Publications
DNA corona on nanoparticles…
By newseditor
Posted 29 Mar
Co-dependent excitatory and…
By newseditor
Posted 29 Mar
A microfluidic platform int…
By newseditor
Posted 28 Mar
Salmonella manipulates macr…
By newseditor
Posted 28 Mar
BHLHE40/41 regulate microgl…
By newseditor
Posted 28 Mar
Presentations
Hydrogels in Drug Delivery
By newseditor
Posted 12 Apr
Lipids
By newseditor
Posted 31 Dec
Cell biology of carbohydrat…
By newseditor
Posted 29 Nov
RNA interference (RNAi)
By newseditor
Posted 23 Oct
RNA structure and functions
By newseditor
Posted 19 Oct
Posters
A chemical biology/modular…
By newseditor
Posted 22 Aug
Single-molecule covalent ma…
By newseditor
Posted 04 Jul
ASCO-2020-HEALTH SERVICES R…
By newseditor
Posted 23 Mar
ASCO-2020-HEAD AND NECK CANCER
By newseditor
Posted 23 Mar
ASCO-2020-GENITOURINARY CAN…
By newseditor
Posted 23 Mar